The Effect of Compressor Speed ​​on Residential Air Conditioning Systems Using R407c and R32 Refrigerant

Authors

  • S. Safril eknik Industri Otomotif, Politeknik STMI Jakarta
  • W.H. Azmi Universiti Malaysia Pahang Al-Sultan Abdullah image/svg+xml
  • T.W. Teh Universiti Malaysia Pahang Al-Sultan Abdullah image/svg+xml
  • R.H. Gurning Politeknik STMI Jakarta image/svg+xml
  • Sukarman Sukarman Universitas Buana Perjuangan Karawang image/svg+xml
  • Khoirudin Khoirudin Universitas Buana Perjuangan Karawang image/svg+xml

DOI:

https://doi.org/10.36805/g02r6b73

Keywords:

Residential Air Conditioning, R32, R407c, Compressor Speed, Coefficient of Performance

Abstract

The demand for residential air conditioning (RAC) systems is expected to increase in the future owing to rising ambient temperatures resulting from global warming. Therefore, it is important to develop and study refrigerants that can improve energy efficiency and thermodynamic performance. This study compares R32 and R407c refrigerants in RAC systems, with an emphasis on the coefficient of performance (COP) and cooling capacity. The research methodology used an experimental approach by testing compressor speeds of 2400, 2700, and 3000 rpm. Based on the test results, R32 consistently performed better than R407c at all compressor speed variations. The COP and cooling capacity of R32 increased significantly by 15.53% and 35.90%, respectively. The stability of R32 performance operated at different compressor speed variations showed an increase in operational adaptability. Finally, R32 was proven to be a more effective and efficient refrigerant than R407c in the RAC system.

References

H. Hasanudin, A. D. Suhendar, A. Abdulah, R. L. Azizah, and A. Al Afgani, "An energy evaluation in a vapor compression refrigeration system utilizing R32 refrigerant," Jurnal Teknik Mesin Mechanical Xplore, vol. 3, no. 2, pp. 67-77, 2023. doi:https://doi.org/10.36805/jtmmx.v3i2.3065

D. F. Blanco-Patiño, J. Niño-Navia, J. I. Garcia-Sepulveda, and C. Nieto-Londoño, "Performance improvement of a centrifugal compressor for cogeneration," International Journal of Thermofluids, vol. 24, p. 100935, 2024. doi: https://doi.org/10.1016/j.ijft.2024.100935

M. Alawadhi and P. E. Phelan, "Review of residential air conditioning systems operating under high ambient temperatures," Energies, vol. 15, no. 8, 2022. doi: https://doi.org/10.3390/en15082880

W. Y. Park et al., "Ensuring the climate benefits of the Montreal Protocol: Global governance architecture for cooling efficiency and alternative refrigerants," Energy Research & Social Science, vol. 76, p. 102068, 2021/06/01/ 2021. doi: https://doi.org/10.1016/j.erss.2021.102068

M. Dilawar and A. Qayoum, "Performance evaluation of novel refrigerant mixtures in an air conditioning system using Al2O3 nanolubricant," Journal of Thermal Analysis and Calorimetry, vol. 148, 09/11 2023. doi: https://doi.org/10.1007/s10973-023-12471-z

R. di Filippo, O. Bursi, and R. Maggio, "Global warming and ozone depletion potentials caused by emissions from HFC and CFC banks due to structural damage," Energy and Buildings, vol. 273, p. 112385, 08/01 2022. doi: https://doi.org/10.1016/j.enbuild.2022.112385

M. I. Ahmed and J. U. Ahamed, "TiO2 nanolubricant: An approach for performance improvement in a domestic air conditioner," Results in Materials, vol. 13, pp. 1-14, 2022. doi: https://doi.org/10.1016/j.rinma.2022.100255

N. Franzen, G. Mills, R. Lamb, D. R. Wiszniewski, and R. Lawton, "The future of refrigerants with GWP of less than 150 " presented at the The Institute of Refrigeration, London, United Kingdom (Institute of Refrigeration event), 15 April, 2021. Available: https://ior.org.uk/events/refrigerants-with-gwp-of-less-150?utm_source=chatgpt.com.

I. A. Hafner, C. H. Gabrielii, and K. Widell, "Refrigeration units in marine vessels: Alternatives to HCFCs and high GWP HFCs," Nordic Council of Ministers, Copenhagen, Denmark9289359412, 2019. doi: https://doi.org/10.6027/TN2019-527

EPA, Sustainability and the US EPA. America: National Academy of Sciences, 2011, Available: https://archive.epa.gov/region9/science/web/pdf/green-book.pdf, Acessed on:01/12/2024.

S. Kasera and S. C. Bhaduri, "Performance of R407C as an alternate to R22: A review," Energy Procedia, vol. 109, pp. 4-10, 2017. doi: https://doi.org/10.1016/j.egypro.2017.03.032

A. S. Norkhujaev and U. A. U. Tashpulatov "Research of refrigerant of R22, R410A, R290 and R32 in different external conditions," The American Journal of Engineering and Technology, vol. 03, no. 05-12, pp. 85-91, 2021. doi: https://doi.org/10.37547/tajet/Volume03Issue05-12

T. Oltersdorf et al., "IEA HPT Annex 54: heat pump systems with low-GWP refrigerants; country report: Germany," IEA, Paris, France (IEA Headquarters)January 2022 2022, Available: https://heatpumpingtechnologies.org/annex54/iea-annex-54-annual-report-2021/, Accessed on: 01/01/2024.

A. Mota-Babiloni, J. Navarro-Esbrí, P. Makhnatch, and F. Molés, "Refrigerant R32 as lower GWP working fluid in residential air conditioning systems in Europe and the USA," Renewable Sustainable Energy Reviews, vol. 80, pp. 1031-1042, 2017. doi: https://doi.org/10.1016/j.rser.2017.05.216

A. R. M. Aminullah et al., "Tribology investigation of automotive air condition (AAC) compressor by using Al2O3/PAG nanolubricant," Journal of Mechanical Engineering, vol. 5, no. 1, pp. 49-61, 01/01 2018, Available: https://ir.uitm.edu.my/id/eprint/36284/1/36284.pdf, Acessed on:11/05/2022.

S. S. Wujek, C. D. Bowers, J. W. Powell, R. Urrego, E. T. Hessell, and T. L. Benanti, "Refrigerant and Lubricant Mass Distribution in a Convertible Split System Residential Air- Conditioner," in International Refrigeration and Air Conditioning Conference at Purdue, West Lafayette, Indiana, United States, 2014, pp. 445–452: Purdue University – Ray W. Herrick Laboratories. Available: https://docs.lib.purdue.edu/cgi/viewcontent.cgi?article=2510&context=iracc. Accessed on 17–20 July 2001.

M. Z. Sharif, W. H. Azmi, A. A. M. Redhwan, R. Mamat, and G. Najafi, "Energy saving in automotive air conditioning system performance using SiO2/PAG nanolubricants," Journal of Thermal Analysis Calorimetry, vol. 135, no. 2, pp. 1285-1297, 2019. doi: https://doi.org/10.1007/s10973-018-7728-3

N. N. M. Zawawi, W. H. Azmi, and M. F. Ghazali, "Performance of Al2O3-SiO2/PAG composite nanolubricants in automotive air-conditioning system," Applied Thermal Engineering, vol. 204, p. 117998, 2022. doi: https://doi.org/10.1016/j.applthermaleng.2021.117998

T. Matsumoto, M. Kaneko, and Y. Kawaguchi, "Evaluations of PVE lubricants for refrigeration and air conditioning system with the low GWP refrigerants," in IOP Conference Series: Materials Science and Engineering, 2017, vol. 232, no. 1, p. 012091: IOP Publishing. doi: https://doi.org/10.18462/iir.icr.2015.696.

Q. Tian et al., "An experimental investigation of refrigerant mixture R32/R290 as drop-in replacement for HFC410A in household air conditioners," International Journal of Refrigeration, vol. 57, pp. 216-228, 2015. doi:https://doi.org/10.1016/j.ijrefrig.2015.05.005

A. R. Al-Badri and A. H. Al-Hassani, "Experimental study of the split-type air conditioner with the variable-speed compressor, variable-speed supply fan, and electronic expansion valve," Wasit Journal of Engineering Sciences, vol. 11, no. 3, pp. 57-70, 2023. doi: https://doi.org/10.31185/ejuow.Vol11.Iss3.458

M. Sruthi Emani and B. Kumar Mandal, "The Use of Natural Refrigerants in Refrigeration and Air Conditioning Systems: A Review," IOP Conference Series: Materials Science and Engineering, vol. 377, no. 1, p. 012064, 2018/06/01 2018. doi: https://doi.org/10.1088/1757-899X/377/1/012064.

S. D. Pawar and N. Korde, "Review paper on compressor oil used in refrigeration system," International Research Journal of Scientific Studies, vol. 2, no. 1, pp. 19-24, 2025. doi: https://doi.org/10.64383/irjss.JAN250103

Daikin, "Data sheet of R32: Instructions for Use and Handling," in "Daikin Chemical Europe GmbH," Germany09/02/2021 2022, Available: https://www.daikinchemicals.co.th/storage/pdf/sds/Refrigerants/R-32.pdf, Accessed on: 02/03/2025.

Gasservei, "Technical Data Sheet R407c," Gasservei, Spanyol01/06/2024 2024, Available: https://gas-servei.com/wp-content/uploads/2024/06/Technical-data-sheet-R-407C-Gas-Servei-1.pdf, Accessed on: 2/3/2025.

Gasservei, "Technical data sheet R410a ", Spanyol2024, Available: https://gas-servei.com/wp-content/uploads/2024/06/Technical-data-sheet-R-410A-Gas-Servei-1.pdf, Accessed on: 2/3/2025.

M. F. Ismail, W. H. Azmi, R. Mamat, and H. M. Ali, "Thermal and tribological properties enhancement of PVE lubricant modified with SiO2 and TiO2 nanoparticles additive," Nanomaterials, vol. 13, no. 1, p. 42, 2023. doi: https://doi.org/10.3390/nano13010042

M. Kaneko, J. I. Yagi, S. Tominaga, M. Tamano, and H. Suto, "The evaluation of PVE (Poly Vinyl Ether) as a lubricant for air conditioning system converted from HCFC22 to Either HFC410A or HFC407C," presented at the International Refrigeration and Air Conditioning Conference, Japan, 12-15 july, 2004. Available: http://docs.lib.purdue.edu/iracc/681.

W. Zeng, Z. Du, B. Gu, Z. Zhang, and Z. Tian, "Thermophysical properties of R32/advanced PVE mixture and parametric analysis on oil transport characteristic of compressor suction line," International Journal of Refrigeration, vol. 135, pp. 243-253, 2022. doi: https://doi.org/10.1016/j.ijrefrig.2021.12.009

X. Jia, J. Wang, Y. Hu, Y. Sun, and X. Wang, "Solubilities of R32 in Polyol Ester and Polyvineyl Ether from 278.15 to 348.15 K," Journal of Chemical & Engineering Data, vol. 65, 07/02 2020. doi: https://doi.org/10.1021/acs.jced.0c00261

Malaysia-Standards, "Energy efficiency and use of renewable energy for non-residential buildings - Code of practice: MS-1525-2014," Department of Standards Malaysia, Malaysia91.040.01, 2014, Available: http://epsmg.jkr.gov.my/images/6/68/MS_1525_2014_fullpdf.pdf, Accessed on: 12/1/2023.

M. Sharif, W. Azmi, N. Zawawi, and M. Ghazali, "Comparative air conditioning performance using SiO2 and Al2O3 nanolubricants operating with Hydrofluoroolefin-1234yf refrigerant," Applied Thermal Engineering, vol. 205, p. 118053, 2022. doi: https://doi.org/10.1016/j.applthermaleng.2022.118053

I. S. Ertesvåg, "Uncertainties in heat-pump coefficient of performance (COP) and exergy efficiency based on standardized testing," Energy buildings, vol. 43, no. 8, pp. 1937-1946, 2011. doi: https://doi.org/10.1016/j.enbuild.2011.03.039

D. Jung, C. Park, and B. Park, "Capillary tube selection for HCFC22 alternatives," International journal of refrigeration, vol. 22, no. 8, pp. 604-614, 1999. doi: https://doi.org/10.1016/S0140-7007(99)00027-4

L. P. Brendel, S. P. Haran, H. Liu, J. E. Braun, and E. A. Groll, "Correlation to predict conditions that lead to liquid-flooding at compressor start-up as a function of evaporator size and fluid properties," International Journal of Refrigeration, vol. 146, pp. 349-356, 2023. doi: https://doi.org/10.1016/j.ijrefrig.2022.11.017

Y. Guo, X. Yang, L. He, Q. Ju, Y. Hou, and S. Chen, "Experimental study on expanding the efficient operating range of two stage series high-speed centrifugal air compressors," Case Studies in Thermal Engineering, vol. 75, p. 107144, 2025. doi: https://doi.org/10.1016/j.csite.2025.107144

S. Bair, J. Jarzynski, and W. O. Winer, "The temperature, pressure and time dependence of lubricant viscosity," Tribology International, vol. 34, no. 7, pp. 461-468, 2001. doi: https://doi.org/10.1016/S0301-679X(01)00042-1

Z. Qin et al., "Research on heat pump air conditioner compressor speed control strategy based on whale algorithm," Case Studies in Thermal Engineering, vol. 53, p. 103939, 2024. doi: https://doi.org/10.1016/j.csite.2023.103939

W. H. Azmi, M. Z. Sharif, T. M. Yusof, R. Mamat, and A. A. M. Redhwan, "Potential of nanorefrigerant and nanolubricant on energy saving in refrigeration system – A review," Renewable and Sustainable Energy Reviews, vol. 69, pp. 415-428, 2017/03/01/ 2017. doi: https://doi.org/10.1016/j.rser.2016.11.207

S. Safril and W. H. Azmi, "Investigation of different compressor speeds to improve the performance of residential air conditioning system using hybrid nanolubricant," Journal of Mechanical Engineering Sciences, vol. 19, no. 1, pp. 10554-10564, 2025. doi: https://doi.org/10.15282/jmes.19.1.2025.10.0827

N. Sitaram and S. Swamy, "Performance improvement of a centrifugal compressor by passive means," International Journal of Rotating Machinery, vol. 2012, no. 1, p. 727259, 2012. doi: https://doi.org/10.1155/2012/727259

Y. Chen, S. Deng, X. Xu, and M. Chan, "A study on the operational stability of a refrigeration system having a variable speed compressor," International Journal of Refrigeration, vol. 31, no. 8, pp. 1368-1374, 2008. doi: https://doi.org/10.1016/j.ijrefrig.2008.04.012

The Effect of Compressor Speed on Residential Air Conditioning Systems Using R407c and R32 Refrigerant

Downloads

Published

2026-02-28

How to Cite

The Effect of Compressor Speed ​​on Residential Air Conditioning Systems Using R407c and R32 Refrigerant. (2026). Jurnal Teknik Mesin Mechanical Xplore, 6(2), 151-162. https://doi.org/10.36805/g02r6b73